ID 70205

Maximum acceleration (a_max) of master-/slave axis is different.

Description

The given maximum allowable accelerations for the gantry master and slave axis are not identical.

 

[FCT-C11// Section: Overview]

Response

Class

1

Warning

Solution

Class

1

Use the same maximum acceleration (see P-AXIS-00008) for both axes.

Parameter

%1:

Logical axis number [-]

Logical axis number of the slave axis P-AXIS-00016

%2:

Error value [mm/s^2 bzw. °/s^2]

Permissible maximum acceleration of slave axis see P-AXIS-00008

%3:

Logical axis number [-]

Logical axis number of the master axis see P-AXIS-00016

%4:

Current value [mm/s^2 bzw. °/s^2]

Permissible maximum acceleration of master axis see P-AXIS-00008

%5:

Corrected value [mm/s^2 bzw. °/s^2]

Correct value for the maximum axis acceleration

Error type

-