ID 70242
The unit of the correction values is invalid. | ||||
Description | An invalid unit for compensation values was specified in an axis compensation value list. P-COMP-00003, P-COMP-00008). However, the input in increments of 1 is only permissible for cross and plane compensation for path resolutions (measuring systems for master and slave axes) (see P-AXIS-00234, P-AXIS-00233).
See [COMP// Section: General compensation value data] | |||
Response | Class | 7 | Warning, compensation is turned off for affected axis | |
Solution | Class | 7 | Cross compensation: Correct parameter P-COMP-00003 Plane compensation: Correct parameter P-COMP-00008. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number of affected axis see P-AXIS-00016 | ||||
%2: | Error value [-] | |||
Faulty unit see P-COMP-00003, P-COMP-00008 | ||||
%3: | Limit value [-] | |||
Parameter value for incremental compensation values | ||||
%4: | Limit value [-] | |||
Parameter value for metrical compensation values | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|