ID 70242

The unit of the correction values is invalid.

Description

An invalid unit for compensation values was specified in an axis compensation value list. P-COMP-00003, P-COMP-00008). However, the input in increments of 1 is only permissible for cross and plane compensation for path resolutions (measuring systems for master and slave axes) (see P-AXIS-00234, P-AXIS-00233).

 

See [COMP// Section: General compensation value data]

Response

Class

7

Warning, compensation is turned off for affected axis

Solution

Class

7

Cross compensation: Correct parameter P-COMP-00003

Plane compensation: Correct parameter P-COMP-00008.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis see P-AXIS-00016

%2:

Error value [-]

Faulty unit see P-COMP-00003, P-COMP-00008

%3:

Limit value [-]

Parameter value for incremental compensation values

%4:

Limit value [-]

Parameter value for metrical compensation values

Error type

2, Error message by data transfer from parameter list into control device.