ID 70261

Terminal reports an error.

Description

The error code is set in the status byte delivered by an intelligent Bus Terminal. With this flag an internal error in the bus terminal is indicated.

Response

Class

8

Error message output, controlled stop of axis.

Solution

Class

6

Eliminate error cause in the terminal, further information about the error cause can possibly be read at LEDs on the terminal or read out from the terminal using diagnostic software. Look at manufacturer documentation.

Parameter

%1:

Current value [-]

Logical axis number of affected axis (see P-AXIS-00016)

%2:

Current value [-]

Character string specifying the type of terminal, e.g.“KL2541“.

%3:

Current value [-]

Status value from the terminal that caused the error.

Error type

-