ID 70263

Homing method (homing_type) of master-/slave axis is different.

Description

The entry P-AXIS-00299 is assigned differently for the master and slave axes of a gantry configuration.

Response

Class

1

Error message output, correction of P-AXIS-00299 of the slave axis to the value of the master axis..

Solution

Class

1

P-AXIS-00299 have the same value assigned to master and slave axis.

Parameter

%1:

Logical axis number [-]

Logical axis number of the slave axis (see P-AXIS-00016).

%2:

Logical axis number [-]

Logical axis number of the master axis (see P-AXIS-00016)

%3:

Error value [-]

Entry P-AXIS-00299 of the slave axis.

%4:

Error value [-]

Entry P-AXIS-00299 of the master axis.

%5:

Corrected value [-]

Corrected entry P-AXIS-00299 of the slave axis.

Error type

-