ID 70334

Function DIST_CTRL ON by actual deselection.

Description

Distance control was deactivated and then re-activated immediately afterwards. After deactivation, wait until the existing compensation offset has finished before re-activating distance control. Alternatively, use the FREEZE command to freeze the current offset so that distance control can stop.

[FCT-M3// Section: Programming]

Response

Class

7

Immediate stop of the axis. The distance control is not turned on.

Solution

Class

6

Enable the distance control only after the correction offset is zero or use the FREEZE command instead.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Block number [-]

Block number in the NC program in which the error occurred.

Error type

11, Error message from position controller.