ID 70366

Permissible value range exceeded for tool change with gear switching.

Description

A tool with a gear speed was replaced for a spindle axis [TOOL// Section: Dynamics and gear data]. However, a parameter value exceeded valid value range during gear switching in the position controller.

Response

Class

7

Closed-loop controlled stop of axis, gear switch is aborted

Solution

Class

6

Correct the parameter value

Parameter

%1:

Upper limit value [-]

Permissible limit value

%2:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%3:

Error value [-]

Invalid parameter value

%4:

Corrected value [-]

Corrected parameter value

%5:

Current value [Increments / 0.1 um ]

Path resolution of the axis see P-AXIS-00234, P-AXIS-00233

Error type

2, Error message by data transfer from parameter list into control device.