ID 70370

Setting homing position not possible because fieldbus does not deliver valid data.

Description

The command to set the homing position was sent via the HLI; however, the fieldbus did not supply any valid position actual values for the axis. Setting the homing position is not possible in this situation.

 

See Adopting the homing position

[HLI// Section: MCControlBoolUnit_SetReferencePosition] for CNC build < 2800

[HLI// Section: lr_mc_control.set_reference_position] for CNC Build > 2800

Response

Class

7

Stop axis.

Solution

Class

6

Set homing position only if actual values valid for the axis are supplied by the fieldbus.

Parameter

%1:

Logical axis number [-]

Log. axis number of the axis (see also P-AXIS-00016).

%2:

Current value [-]

Flag indicates if fieldbus delivers valid actual positions.

Error type

-