ID 70375

Inconsistent data for spindle revolution monitoring

Description

Data for spindle speed monitoring is inconsistent.

With spindle speed monitoring, limit speed and activation are stored inverted and non-inverted.

To compare the two values, the second (inverted value) is re-inverted and then compared with the first value. If these two values differ this error message is output.

Possible reasons for this error message are:

  • Configuration error, data was entered incorrectly in the configuration data.
  • Error in data transfer.

Response

Class

5

Error message output, immediate stop of axis

Solution

Class

6

In case of a configuration error, correct the data and restart the controller.

In case of a transmission error, reset the controller.

Parameter

%1:

Logical axis number [-]

Log. axis number (see P-AXIS-00016).

%2:

Current value [1µm/s or 0.001°/s]

First value.

%3:

 

Second (inverted) value, re-inverted, must result in same value as Kennung_2.

%4:

 

First value inverted, must result in same value as Kennung_5.

%5:

 

Second (inverted) value.

Error type

11, Error message from position controller.