ID 70380

Maximum permissible path exceeded for zero pulse search or encoder overflow search.

Description

During homing, the maximum permissible path set in parameter P-AXIS-00404 for searching the zero pulse or the encoder overflow was exceeded.

Possible reasons for this error message are:

  • Invalid set value of P-AXIS-00404.
  • Encoder defective or incorrectly wired.
  • Incorrect parameterisation of drive amplifier with respect to encoder evaluation.
  • Incorrect configuration of process data between drive and CNC.

Response

Class

7

Stop of axis, output of error message.

Solution

Class

6

Possible solutions:

  • Set correct value of P-AXIS-00404
  • Replace encoder or wire correctly.
  • Correct parameterisation of encoder evaluation in drive amplifier
  • Check and correct configuration of process data between drive and CNC

Parameter

%1:

Logical axis number [-]

Axis number (P-AXIS-00016).

%2:

Current value [-]

Maximum permissible path during zero pulse search (value of P-AXIS-00404)

%3:

Limit value [-]

Covered distance since start of zero pulse search.

%4:

Current value [-]

Current actual axis position in increments.

%5:

Current value [-]

Axis position at start of zero pulse search in increments.

Error type

1, Error message from NC program.