ID 70384

The scaled limit value is smaller than the minimum value of the configured data type.

Description

The scaled (see P-AXIS-00401) value of parameter P-AXIS-00408 is smaller than the minimum value of the data type set with parameter P-AXIS-00399.

Response

Class

1

Warning output, P-AXIS-00408 is automatically limited to the minimum value according to P-AXIS-00399.

Solution

Class

1

P-AXIS-00408 value must be adjusted.

Parameter

%1:

Logical axis number [-]

 

%2:

Current value [-]

Value of P-AXIS-00396 for identification of drive function.

%3:

Error value [-]

Parameterized value of P-AXIS-00408.

%4:

Current value [-]

Scaling factor (see P-AXIS-00401).

%5:

Limit value [-]

Minimum possible value for P-AXIS-00408 taking into account P-AXIS-00399 and P-AXIS-00401, simultaneously corrected value.

Error type

11, Error message from position controller.