ID 70425

Timeout after deactivating the additional interface. Filter not within position window.

Description

To smooth command values, a PT2 filter can be activated in the position controller for the additive command value interface (see P-AXIS-00438). if the interface is disabled, the axis can run through the filter slightly. The CNC generates this warning message, if the axis is not in standstill within a certain amount of time.

See also:

[HLI// Section: External axis commanding] for CNC build < 2800

[HLI// Section: External axis commanding] for CNC build > 2800

Response

Class

1

Warning output

Solution

Class

1

Reduce time constant P-AXIS-00438 of PT2 filter

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Upper limit value [µs]

Elapsed time after the deactivation of the additive command value interface

%3:

Upper limit value [-]

Elapsed CNC cycles after the deactivation of the additive command value interface

%4:

Current value [0.1 µm or 0.0001°]

Position lag: Filter output - filter input

%5:

Current value[-]

Time constant P-AXIS-00438 of the used PT2 filter

Error type

11, Error message from position controller.