ID 70526
The axis should be compensated with a Volumetric Compensation but has no release. | ||||
Description | An axis that is part of a Volumetric Compensation is about to receive a correction value but the axis is not released. | |||
Response | Class | 7 | Controlled halt of the axis, the control loop is closed. | |
Solution | Class | 6 | Reset CNC, issue axis release | |
Parameter | %1: | Compensation index [-] | ||
ID of Volumetric Compensation | ||||
%2: | Logical axis number [-] | |||
Logical axis number (P-AXIS-00016 of axis affected | ||||
%3: | Current value [* 10^-4 Incr] | |||
Preceding correction value | ||||
%4: | Current value [* 10^-4 Incr] | |||
Current correction value | ||||
%5: | Current value [* 10^-4 Incr] | |||
Following correction value | ||||
Error type | 11, Error message from position controller. | |||
|