ID 90031

Tool radius exceeds range at channel block sequence circle-circle.

Description

Tool radius exceeds range at channel block sequence circle-circle, a calculation of the intersection of the circles is not possible.

Response

Class

2

Abort NC program processing.

Solution

Class

6

Use of a tool with a smaller radius

Parameter

%1:

Current value [0.1 µm or 0.0001°]

Available width of tool diameter

%2:

Lower limit value [0.1 µm or 0.0001°]

Tool diameter

%3:

Current value [0.1 µm or 0.0001°]

Diameters of the first programmed circle and/or sector of a circle

%4:

Current value [0.1 µm or 0.0001°]

Diameters of the second programmed circle and/or sector of a circle

%5:

Current value [0.1 µm or 0.0001°]

Distance of the circle centre points

Error type

1, Error message from NC program.