ID 90179

No valid intersection point with G236 selection found.

Description

At selection of TRC with mode G236, no valid selection point could be determined.

Possible caused through short motion blocks with a corresponding great \tool radius.

The direct selection mode (G138) of TRC is used.

Response

Class

1

NC program processing is continued

Solution

Class

1

Check and modify the motion blocks at TRC selection

Error type

1, Error message from NC program.