ID 110061

Number of revolutions in the event of modulo errors is less than 0.

Description

The number of modulo revolutions P-AXIS-00125 is zero (nil). For an active modulo compensation P-AXIS-00120 the number must be greater than zero (nil).

Response

Class

1

Initialization of Modulo revolutions with default value.

Solution

Class

1

Correction of the value in the parameter list

Parameter

%1:

Logical axis number [-]

P-AXIS-00016

%2:

Current value [-]

P-AXIS-00125

%3:

Limit value [-]

 

%4:

Corrected value [-]

P-AXIS-00125

Error type

2, Error message by data transfer from parameter list into control device.