ID 110113

Measuring feed rate is 0.

Description

The parameter P-AXIS-00215 for measurement feed motion is smaller than minimum permissible value.

The parameter value is set to default minimum value.

Response

Class

1

None.

Solution

Class

1

Set measurement feed greater than minimum value.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0,001°/s]

Current measurement feed P-AXIS-00215.

%3:

Corrected value [1µm/s or 0,001°/s]

Corrected measurement feed @@P-AXIS-00215.

Error type

2, Error message by data transfer from parameter list into control device.