ID 110114
Measurement speed exceeds limit. | ||||
Description | The parameter P-AXIS-00215 for measurement speed is greater than the maximum permissible value. The parameter value is set to default maximum value. | |||
Response | Class | 1 | None. | |
Solution | Class | 1 | Set measurement speed P-AXIS-00215 to smaller than maximum value. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected. | ||||
%2: | Current value [1µm/s or 0.001°/s] | |||
Current measurement speed P-AXIS-00215. | ||||
%3: | Limit value [1µm/s or 0.001°/s] | |||
Maximum value for measurement speed. | ||||
%4: | Corrected value [1µm/s or 0.001°/s] | |||
Corrected measurement speed P-AXIS-00215. | ||||
Error type | 2, Error message on data transfer of parameter lists to controller. | |||
|