ID 110114
Measuring feed rate exceeds limit. | ||||
Description | The parameter P-AXIS-00215 for measurement feed motion is greater than maximum permissible value. The parameter value is set to default maximum value. | |||
Response | Class | 1 | None. | |
Solution | Class | 1 | Set measurement feed rate P-AXIS-00215 smaller than maximum value. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis. | ||||
%2: | Current value [1µm/s or 0,001°/s] | |||
Current measurement feed P-AXIS-00215. | ||||
%3: | Limit value [1µm/s or 0.001°/s] | |||
Maximum value for measurement feedrate. | ||||
%4: | Corrected value [1µm/s or 0,001°/s] | |||
Corrected measurement feed @@P-AXIS-00215. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|