ID 110114

Measuring feed rate exceeds limit.

Description

The parameter P-AXIS-00215 for measurement feed motion is greater than maximum permissible value.

The parameter value is set to default maximum value.

Response

Class

1

None.

Solution

Class

1

Set measurement feed rate P-AXIS-00215 smaller than maximum value.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0,001°/s]

Current measurement feed P-AXIS-00215.

%3:

Limit value [1µm/s or 0.001°/s]

Maximum value for measurement feedrate.

%4:

Corrected value [1µm/s or 0,001°/s]

Corrected measurement feed @@P-AXIS-00215.

Error type

2, Error message by data transfer from parameter list into control device.