ID 110114

Measurement speed exceeds limit.

Description

The parameter P-AXIS-00215 for measurement speed is greater than the maximum permissible value.

The parameter value is set to default maximum value.

Response

Class

1

None.

Solution

Class

1

Set measurement speed P-AXIS-00215 to smaller than maximum value.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Current value [1µm/s or 0.001°/s]

Current measurement speed P-AXIS-00215.

%3:

Limit value [1µm/s or 0.001°/s]

Maximum value for measurement speed.

%4:

Corrected value [1µm/s or 0.001°/s]

Corrected measurement speed P-AXIS-00215.

Error type

2, Error message on data transfer of parameter lists to controller.