Rapid feed rate for operating mode "incremental mode" exceeds limit. | ||||
Description | For manual operation mode in continuous jog mode, the parameter P-AXIS-00210 sets the rapid mode velocity. The rapid mode velocity P-AXIS-00210 is set to the permissible maximum value. | |||
Response | Class | 1 | None. | |
Solution | Class | 1 | P-AXIS-00210 must be smaller than maximum value. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis. | ||||
%2: | Current value [1µm/s or 0,001°/s] | |||
Current rapid mode velocity P-AXIS-00210. | ||||
%3: | Upper limit value [1µm/s or 0,001°/s] | |||
Maximum permissible velocity. | ||||
%4: | Corrected value [1µm/s or 0,001°/s] | |||
Corrected rapid mode velocity P-AXIS-00210. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|