ID 110141

Incremental feed rate is greater than the maximum permissible feed rate.

Description

With manual mode in “continuous jog mode”, the parameter P-AXIS-00077 defines the continuous jog velocity. The specified value is greater than the permissible maximum value and is limited to this value.

Response

Class

1

Warning and correction of parameter.

Solution

Class

1

Check and correct the parameter P-AXIS-00077

Parameter

%1:

Logical axis number

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0.001°/s]

Current velocity P-AXIS-00077.

%3:

Upper limit value [1µm/s or 0.001°/s]

Maximum permissible velocity.

%4:

Corrected value [1µm/s or 0.001°/s]

Corrected velocity P-AXIS-00077.

%5:

Current value [-]

Array index of the incorrect entry

Error type

2, Error message by data transfer from parameter list into control device.

[1µm/s or 0.001°/s]