ID 110143

Incremental jog velocity is greater than maximum incremental jog velocity.

Description

For manual operation mode in incremental jog, the parameter P-AXIS-00076 sets the jog velocity.

The jog velocity is set to the maximum value.

Response

Class

1

None.

Solution

Class

1

P-AXIS-00076 must be smaller than maximum value.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [1µm/s or 0.001°/s]

Current jog velocity P-AXIS-00076.

%3:

Upper limit value [1µm/s or 0.001°/s]

Maximum permissible jog velocity.

%4:

Corrected value [1µm/s or 0.001°/s]

Corrected jog velocity P-AXIS-00076.

%5:

Current value [-]

Array index of the incorrect entry

Error type

2, Error message by data transfer from parameter list into control device.