ID 110145

Positive relative manual mode offset limit negative.

Description

The positive offset limit P-AXIS-00138 for the positive motion range in active manual mode is less than 0. The positive offset limit is corrected to the default value.

Response

Class

1

None.

Solution

Class

1

Set positive offset limit P-AXIS-00138 greater than 0.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Current value [-]

Current value P-AXIS-00138.

%3:

Current value [-]

Corrected value P-AXIS-00138.

%4:

Corrected value [-]

 

%5:

Corrected value [-]

 

Error type

2, Error message on data transfer of parameter lists to controller.