ID 110210

Unknown type of axis corrected to translatory axis type.

Description

The axis type specified in the parameter list P-AXIS-00018 is unknown.

Response

Class

1

The type is set to P-AXIS-00018 =1.

Solution

Class

1

Correct the value in the parameter list.

Parameter

%1:

Logical axis number [-]

P-AXIS-00016

%2:

Current value [-]

P-AXIS-00018

%3:

Corrected value [-]

P-AXIS-00018

Error type

2, Error message by data transfer from parameter list into control device.