ID 110236

Leadscrew error compensation activated without compensation value list.

Description

The CNC detects an inconsistent parameterization regarding leadscrew error compensation.

 

In an axis configuration list, leadscrew error compensation was activated via parameter P-AXIS-00175.

 

The CNC now expects the information in which path and under which name a corresponding compensation value list can be found. To do this, the data in parameters P-STUP-00016, P-STUP-00017, P-STUP-00036 must be parameterized correctly in start-up list.

 

In the corresponding compensation value list, the parameters P-COMP-00001 and P-COMP-00020 must also be entered correctly for leadscrew error compensation.

Response

Class

1

CNC disables leadscrew error compensation.

Solution

Class

7

Check parameters
P-STUP-00016
P-STUP-00017
P-STUP-00036
P-COMP-00001
P-COMP-00020 for consistent data.

If leadscrew error compensation is not desired, set parameter P-AXIS-00175 to the value 0.

Parameter

%1:

Logical axis number [-]

Parameter P-AXIS-00016 from an axis configuration list in which the leadscrew error compensation was activated via P-AXIS-00175.

Error type

2, Error message by data transfer from parameter list into control device.