ID 110304

Request for spindle interface, but axis is not a spindle.

Description

A spindle is defined in the channel parameter list (SDA parameter) and the logical axis number for the spindle is parametrised by parameter P-CHAN-00036.

In the axis configuration list with the corresponding logical axis number (P-AXIS-00016), the axis type (P-AXIS-00018) is not the value for a spindle (0x0004).

Response

Class

2

CNC start-up is continued but no axes are available in the channel where the spindle was parametrised.

Solution

Class

7

When the axis with this logical axis number is a spindle, set the value for the axis type P-AXIS-00018 to the value for a spindle (0x0004).

If the spindle has a different logical axis number, change the parameter P-CHAN-00036 .

Parameter

%1:

Expected value [-]

The parameter P-AXIS-00018 in the axis configuration list must have this value if the axis is to be configured as a spindle.

%2:

Incorrect value [-]

Current value of parameter P-AXIS-00018 in the axis configuration list.

%3:

Logical axis number [-]

The parameter P-AXIS-00016 in the axis configuration list where the parameter P-AXIS-00018 has the invalid value.

Error type

3, Error message from communication.