ID 110304

Spindle interface requested although axis is not a spindle (see channel parameter).

Description

A spindle is defined in channel parameter list (SDA parameter) and the logical axis number for the spindle is parametrized by parameter P-CHAN-00036.

In the axis configuration list with the corresponding logical axis number ( P-AXIS-00016), the axis type (P-AXIS-00018) is not the value for a spindle (0x0004).

Response

Class

2

Start-up of CNC is continued, but no axis is available in the channel where the spindle was parametrized.

Solution

Class

7

When the axis with this logical axis number is a spindle, set the value for axis type P-AXIS-00018 to the value for a spindle (0x0004).

If spindle has another logical axis number, change P-CHAN-00036 .

Parameter

%1:

Expected value [-]

Parameter P-AXIS-00018 in the axis configuration list must have this value, if the axis is to be configured as spindle.

%2:

Error value [-]

Current value of parameter P-AXIS-00018 in an axis configuration list.

%3:

Logical axis number [-]

Parameter P-AXIS-00016 from the axis configuration list in which parameter P-AXIS-00018 has the invalid value.

Error type

3, Error message from communication.