ID 110334

Reduced Speed range limitation pos. is greater than pos. SLS.

Description

The positive range limit for Reduced Speed in the safety zones P-AXIS-00085, P-AXIS-00097 is greater than the positive software limit switch. The positive range limit is set to the positive software limit switch position.

Response

Class

1

None.

Solution

Class

1

Select positive range limit smaller than positive software limit switch.

Parameter

%1:

Logical axis number [0.1 µm or 0,0001°]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [0.1 µm or 0,0001°]

Current positive range limit.

%3:

Upper limit value [0.1 µm or 0,0001°]

Positive software limit switch P-AXIS-00178.

%4:

Corrected value [0.1 µm or 0.0001°]

Corrected positive range limit.

Error type

2, Error message by data transfer from parameter list into control device.