ID 110362

Number of cycles for coupling/decoupling temperature compensation exceeds maximum limit.

Description

The specified number of cycles for coupling(decoupling the temperature compensation value is set by the parameter lr_param.temp_comp_n_cycles (P-AXIS-00275). The specified value is too high.

 

See [FCT-C5// Temperature compensation]

Response

Class

1

Parameter is limited to maximum value range.

Solution

Class

1

Correct parameter.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Error value [-]

Parameterised value of P-AXIS-00275

%3:

Upper limit value [-]

Maximum value for P-AXIS-00275

%4:

Corrected value [-]

New value for P-AXIS-00275

Error type

2, Error message by data transfer from parameter list into control device.