ID 110374

Command position for DSE corrected to MODE_ACC_LINEAR.

Description

With DSE, P-AXIS-00122 and P-AXIS-00123 must be set to MODE_ACC_LINEAR (linear handling of values) to scale actual and command positions. Only then can display data match in actual and command positions and position lag.

Response

Class

1

Warning output. P-AXIS-00123 is set to MODE_ACC_LINEAR.

Solution

Class

1

Set value for P-AXIS-00123 to MODE_ACC_LINEAR.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [-]

Current value for P-AXIS-00123.

%3:

Corrected value [-]

Corrected value for P-AXIS-00123.