ID 110388
Max. Motion path for homing GANTRY slave is smaller than 0. | ||||
Description | A value smaller than zero (nil) for P-AXIS-00284 was entered in the axis parameter list. The value is corrected automatically by taking the absolute value. | |||
Response | Class | 1 | Closed-loop controlled halt of axis | |
Solution | Class | 1 | Check value of P-AXIS-00284. | |
Parameter | %1: | Logical axis number [-] | ||
For logical axis number of concerned axis, see P-AXIS-00016 | ||||
%2: | Current value [0.1 µm or 0,0001°] | |||
Current setting value, see P-AXIS-00284 | ||||
%3: | Limit value [0.1 µm or 0.0001°] | |||
Lower limit value for P-AXIS-00284 (0) | ||||
%4: | Corrected value [-] | |||
Corrected value. | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|