ID 110417

Invalid value for parameter probing_input_number was corrected.

Description

The axis was set as probing axis (P-AXIS-00118) and an invalid value was specified for the probing input to be used at the drive (parameter P-AXIS-00295).

Response

Class

1

Warning output, correct value of P-AXIS-00295 to 1.

Solution

Class

1

In the axis parameter list, assign a valid value (1 or 2) to parameter P-AXIS-00295. In the drive, the latch function must be assigned to the digital input used by assigning the value 26 to drive parameter IN1MODE or IN2MODE.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis (see P-AXIS-00016).

%2:

Incorrect value [-]

 

%3:

Lower limit value [-]

 

%4:

Upper limit value [-]

 

%5:

Corrected value [-]

 

Error type

2, Error message on data transfer of parameter lists to controller.