ID 110418

Value for encoder_range is outside the permissible range.

Description

Parameter P-AXIS-00296 is out of its permissible range.

Response

Class

1

Warning output, corrected the value of P-AXIS-00296. If P-AXIS-00296 was configured below the minimum value, P-AXIS-00296 is set to the minimum value, otherwise, if the maximum value was exceeded, P-AXIS-00296 is limited to the maximum value.

Solution

Class

1

Set a valid value for P-AXIS-00295 in the axis parameter list.

Parameter

%1:

Logical axis number [-]

Logical axis identifier of concerned axis (see P-AXIS-00016).

%2:

Current value [-]

Index of the invalid entry in the lr_hw[] array. A value of 0 means lr_hw[0].encoder_range is erroneous.

%3:

Lower limit value [-]

 

%4:

Upper limit value [-]

 

%5:

Corrected value [-]

 

Error type

2, Error message by data transfer from parameter list into control device.