ID 110420

Invalid value for parameter max_reference_position_offset entered.

Description

The value of parameter P-AXIS-00298 (permissible distance to homing to suppress a gantry error) is outside the permissible data range.

Response

Class

1

Warning output, value corrected to 0.

Solution

Class

1

Change parameter P-AXIS-00298.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Lower limit value [0.1 µm or 0.0001°]

Permissible minimum value of P-AXIS-00298.

%3:

Upper limit value [0.1 µm or 0.0001°]

Permissible maximum value of P-AXIS-00298.

%4:

Incorrect value [0.1 µm or 0.0001°]

Current (incorrect) value of P-AXIS-00298.

%5:

Corrected value [0.1 µm or 0.0001°]

Corrected value of P-AXIS-00298.

Error type

2, Error message on data transfer of parameter lists to controller.