ID 110445
Phasing: jerk inadmissible. | ||||
Description | The value for the phasing jerk j_phasing may not be zero or greater than the maximum jerk. The maximum jerk is then half the value of the maximum acceleration divided by the minimum permissible ramp time. | |||
Response | Class | 1 | Warning output. The value of j_phasing is automatically set to the maximum jerk. | |
Solution | Class | 1 | Set value of j_phasing greater than zero and less than the maximum jerk. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected. | ||||
%2: | Current value [1mm/2^3 or 1°/s^3] | |||
Current value of j_phasing. | ||||
%3: | Corrected value [1mm/2^3 or 1°/s^3] | |||
Value of j_phasing corrected to the maximum jerk. | ||||
Error type | 2, Error message on data transfer of parameter lists to controller. | |||
|