ID 110447

Invalid value for parameter P979_3 was corrected.

Description

The 'reading absolute position from drive' function (P-AXIS-00315) was activated in the axis parameter list, and no value or a value outside the permissible value range was assigned to parameter P-AXIS-00316.

This parameter is initialised with –1 by default. This error message is output if no entry was made in the axis parameter list.

Response

Class

1

The value of P-AXIS-00316 is automatically corrected.

Solution

Class

1

Change value of P-AXIS-00316 or enter an entry in the axis parameter list.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Incorrect value [-]

Current (incorrect) value of P-AXIS-00316.

%3:

Lower limit value [-]

Permissible minimum value of P-AXIS-00316.

%4:

Upper limit value [-]

Permissible maximum value of P-AXIS-00316.

%5:

Corrected value [-]

Corrected value of P-AXIS-00316.

Error type

2, Error message on data transfer of parameter lists to controller.