ID 110450

Modification of parameter p1042 requires restart of the control.

Description

Parameter P-AXIS-00316 cannot be changed while the CNC kernel is running. The new value is not adopted; the previous active value remains valid.

Response

Class

1

None.

Solution

Class

1

Reboot the controller after changing P-AXIS-00316.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

%2:

Current value [-]

Current value of P-AXIS-00316.

%3:

Corrected value [-]

Corrected (old) value of P-AXIS-00316.

Error type