ID 110454

Value for quantization of measurement system increments is zero.

Description

The value for the quantization of measurement system increments is zero. It must be greater zero. The default setting consists of one increment.

For spindle revolution monitoring (see FCT-S1// Section: Spindle monitoring and during the check of the exact stop of axes (see P-AXIS-00236), a check is made whether the current values are within a specified tolerance. Parameter P-AXIS-00323 is the minimum size of the tolerance window after conversion of the tolerance limits into the resolution of the measurement system (default setting: 1 increment).

Response

Class

1

Correct parameter P-AXIS-00323 to default value 1

Solution

Class

1

Correct parameter P-AXIS-00323

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis, see P-AXIS-00016

%2:

Incorrect value [-]

Specified value, see P-AXIS-00323

%3:

Corrected value [-]

Corrected value see P-AXIS-00323

Error type

-