ID 110459
Activation of conventional and adaptive feedforward control at the same time not possible. | ||||
Description | In the parameter vorsteuer.vorsteuerung (P-AXIS-00223), both conventional feedforward control (bits 0 ... 3) and adaptive feedforward control (bits 4 ... 6) were activated. | |||
Response | Class | 1 | Warning and correction of parameter. Feedforward control is deactivated. | |
Solution | Class | 1 | Check and modify the parameter P-AXIS-00223. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number (P-AXIS-00016) of concerned axis | ||||
%2: | Current value [-] | |||
Parameterised value of P-AXIS-00223 | ||||
%3: | Corrected value [-] | |||
New value of P-AXIS-00223 | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|