ID 110476
Compensation value change in leadscrew error compensation exceeds value range. | ||||
Description | The difference between successive compensation values (see P-COMP-00023, P-COMP-00024) in the compensation value table for leadscrew error compensation is greater than permissible. If metrical input in 0.1 µm is used (see P-COMP-00017), the compensation values in the controller are multiplied with the resolution of the axis (see P -AXIS-00234/P-AXIS-00233). | |||
Response | Class | 3 | Leadscrew error compensation is not activated. | |
Solution | Class | 7 | Correct compensation value table of leadscrew error compensation. Reduce the distance of the interpolation points (see P-COMP-00018) or insert additional intermediate points in the compensation table to reduce the compensation value change per interval | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Current value [-] | |||
Field index of the affected correction value in the compensation value table | ||||
%3: | Current value [increments] | |||
Current compensation value in increments (see P-COMP-00023/P-COMP-00024) | ||||
%4: | Current value [increments] | |||
Next compensation value in increments (see P-COMP-00023/P-COMP-00024) | ||||
%5: | Error value [increments] | |||
Difference between both compensation values in increments | ||||
Error type | - | |||
|