ID 110476

Compensation value change in leadscrew error compensation exceeds value range.

Description

The difference between successive compensation values (see P-COMP-00023P-COMP-00024) in the compensation value table for leadscrew error compensation is greater than permissible. If metrical input in 0.1 µm is used (see P-COMP-00017), the compensation values in the controller are multiplied with the resolution of the axis (see P -AXIS-00234/P-AXIS-00233).

Response

Class

3

Leadscrew error compensation is not activated.

Solution

Class

7

Correct compensation value table of leadscrew error compensation.

Reduce the distance of the interpolation points (see P-COMP-00018) or insert additional intermediate points in the compensation table to reduce the compensation value change per interval

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Current value [-]

Field index of the affected correction value in the compensation value table

%3:

Current value [increments]

Current compensation value in increments (see P-COMP-00023/P-COMP-00024)

%4:

Current value [increments]

Next compensation value in increments (see P-COMP-00023/P-COMP-00024)

%5:

Error value [increments]

Difference between both compensation values in increments

Error type

-