ID 110478

Compensation value in leadscrew error compensation exceeds value range.

Description

If the compensation values are entered metrically in 0,1 µm (see P-COMP-00017), the controller converts the values into increments by multiplying them with the resolution of the axis (see P-AXIS-00234/P-AXIS-00233). However, the resulting value exceeds the permissible value range.

Response

Class

3

The leadscrew error compensation is not activated.

Solution

Class

7

Compensation value table of the leadscrew error compensation.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Error value [increments]

Compensation value in increments (see P-COMP-00023/P-COMP-00024)

%3:

Lower limit value [increments]

Minimum permissible value

%4:

Upper limit value [increments]

Maximum permissible value

%5:

Current value [-]

Table index of affected compensation value

Error type

2, Error message by data transfer from parameter list into control device.