ID 110479
Distance of interpolation points in leadscrew error compensation exceeds value range. | ||||
Description | During leadscrew error compensation, if the distance between the correction values (see P-COMP-00018) is entered metrically in 0.1 µm (see P-COMP-00017) , the controll converts the value into increments by multiplying it by the resolution of the axis (see P-AXIS-00234/P-AXIS-00233). The resulting value exceeds the range of values. | |||
Response | Class | 3 | The leadscrew error compensation is not activated. | |
Solution | Class | 7 | Compensation value table of the leadscrew error compensation. Reduce the interpolation point distance (see P-COMP-00018) in the compensation value table. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Error value [increments] | |||
Interpolation point distance in increments | ||||
%3: | Lower limit value [increments] | |||
Minimum permissible spacing of interpolation points in increments. | ||||
%4: | Upper limit value [increments] | |||
Maximum permissible spacing of interpolation points in increments. | ||||
%5: | Current value [0.1 µm or 0,0001°] | |||
Interpolation point distance P-COMP-00018 from compensation value table | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|