ID 110479

Distance between interpolation points in leadscrew error compensation exceeds range of values.

Description

During leadscrew error compensation, if the distance between compensation values (see P-COMP-00018) is entered metrically in 0.1 µm (see P-COMP-00017) , the controller converts the value into increments by multiplying it by the resolution of the axis (see P-AXIS-00234/P-AXIS-00233). The resulting value exceeds the range of values.

Response

Class

3

Leadscrew error compensation is not activated.

Solution

Class

7

Correct the compensation value list of the leadscrew error compensation.

Reduce the distance between interpolation points (see P-COMP-00018) in the compensation value list.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Incorrect value [increments]

Distance between Interpolation points in increments

%3:

Lower limit value [increments]

Minimum permissible distance between interpolation points in increments.

%4:

Upper limit value [increments]

Maximum permissible distance between interpolation points in increments.

%5:

Current value [0.1 µm or 0.0001°]

Distance between Interpolation points P-COMP-00018 in compensation value list

Error type

2, Error message on data transfer of parameter lists to controller.