ID 110480
Distance between interpolation points in leadscrew error compensation exceeds range of values. | ||||
Description | During leadscrew error compensation, if the interpolation points P-COMP-00025 in the compensation value list are entered metrically in 0.1 µm (see P-COMP-00017), the positions in the controller are converted into increments by multiplying them by the resolution of the axis (see P-AXIS-00234 / P-AXIS-00233). However, the resulting distance between two interpolation points exceeds the permissible value range. | |||
Response | Class | 3 | Leadscrew error compensation is not activated. | |
Solution | Class | 7 | Correct the compensation value list of the leadscrew error compensation. Insert additional interpolation points P-COMP-00025 in the compensation value list to reduce the distance between the interpolation points. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of axis affected | ||||
%2: | Current value [-] | |||
List index of affected interpolation point | ||||
%3: | Current value [increments] | |||
Position of affected interpolation point in increments | ||||
%4: | Current value [increments] | |||
Position of next interpolation point in increments | ||||
%5: | Incorrect value [increments] | |||
Distance between the two interpolation points in increments. | ||||
Error type | - | |||
|