ID 110496

Position window of axis filter too small.

Description

The tolerance window P-AXIS-00351 specified for the axis filters was too small. The program waits for the position window to be reached provided the axis filters are active (| unfiltered command value – filtered command value| < P-AXIS-00351) at reset, axis position request or exact stop. The permissible tolerance window cannot be specified as too small due to the restricted computational accuracy.

Response

Class

1

Warning output, automatic correction of P-AXIS-00351.

Solution

Class

1

Correct value in parameter list.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Error value [0.1 µm or 0,0001°]

Incorrect value for position window P-AXIS-00351

%3:

Lower limit value [0.1 µm or 0,0001°]

Smallest permissible value for position window P-AXIS-00351

%4:

Corrected value [0.1 µm or 0.0001°]

Corrected value of P-AXIS-00351

Error type

2, Error message by data transfer from parameter list into control device.