ID 110515

Using real-time bits for probing and homing at the same time not possible.

Description

The axis is to be used for probing, so the real-time status and control bits of the SERCOS control and status word are assigned (P-AXIS-00118). At the same time, the real-time control and status bits are to be used for the drive-supported CNC-controlled homing, (P-AXIS-00387 has the value 1).

This double use of the real-time bits is not possible.

Response

Class

1

Probing is deactivated.

Solution

Class

1

Configure transfer of the control and status bits for homing via signal control and signal status word and adapt P-AXIS-00387 accordingly.

Parameter

%1:

Logical axis number [-]

Log. Axis number (see also P-AXIS-00016).

%2:

Incorrect value [-]

Value of P-AXIS-00387.

%3:

Incorrect value [-]

Value of P-AXIS-00118.

%4:

Incorrect value [-]

Corrected value of P-AXIS-00118.

Error type

2, Error message on data transfer of parameter lists to controller.