ID 110524

Modulo range exceeds data range because of resolution settings.

Description

Modulo range defined through the parameters P-AXIS-00127 and P-AXIS-00126 was exceeded.

This is caused by a change in distance resolution. This is set via parameters P-AXIS-00234 and P-AXIS-00233.

Response

Class

3

None

Solution

Class

7

Check and modify the modulo limits and the parameters of distance resolution.

Parameter

%1:

Logical axis number [-]

Log. axis number P-AXIS-00016

%2:

Current value [-]

P-AXIS-00126

%3:

Limit value [-]

Maximum possible value for P-AXIS-00126 with constant distance resolution

%4:

Current value [-]

P-AXIS-00127

%5:

Limit value [-]

Minimum possible value for P-AXIS-00127 with constant distance resolution

Error type

2, Error message on data transfer of parameter lists to controller.