Decreasing path parameter not allowed. | ||||
Description | When configuring distance dependent dynamic weighting, the path parameters (P-AXIS-00432) are not configured in ascending order. | |||
Response | Class | 1 | Warning output, the dynamic weighting factors of the entry with the smaller path parameter are replaced by the dynamic weighting factors of the entry with the bigger path parameter. | |
Solution | Class | 1 | Sort the entries for the dynamic weighting factors in ascending order. | |
Parameter | %1: | Logical axis number [-] | ||
| ||||
%2: | Current value [0.1 10^-3 mm or ø] | |||
| ||||
%3: | Current value [0.1 10^-3 mm or ø] | |||
| ||||
%4: | Corrected value [0.1 10^-3 mm or ø] | |||
| ||||