ID 110571

Positive absolute ACS manual mode limit exceeds positive software limit switch.

Description

The absolute positive movement limit P-AXIS-00493 for the movement range in active manual operation mode is greater than the negative software limit switch P-AXIS-00178. The absolute positive movement limit is set to the positive software limit switch.

Response

Class

1

None.

Solution

Class

1

Set positive motion limit P-AXIS-00493 smaller than positive software limit switch.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [-]

Current value for positive movement limit P-AXIS-00493.

%3:

Limit value [-]

Current value für positive software limit P-AXIS-00178.

%4:

Corrected value [-]

Corrected value for positive motion limit P-AXIS-00493.

Error type

2, Error message by data transfer from parameter list into control device.