ID 110587
Selected measuring input is unsupported by the drive. | ||||
Description | In parameter P-AXIS-00517 "kenngr.measure.input" the number of the measuring input used for a measurement run (e.g. G100) is defined. However, the setting found is invalid because the selected Measurement input is not available on the drive. In dependency of the drive type, permissible values for the measuring input are 1 or 2. | |||
Response | Class | 1 | Warning and correction of parameter P-AXIS-00517 | |
Solution | Class | 1 | Parameter P-AXIS-00517 correct number of measuring input | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number P-AXIS-00016 of concerned axis | ||||
%2: | Current value [-] | |||
Selected measuring signal source P-AXIS-00516 | ||||
%3: | Error value [-] | |||
Incorrect setting for measuring input P-AXIS-00517 | ||||
%4: | Upper limit value [-] | |||
Maximum permissible value for P-AXIS-00517 for this drive type | ||||
%5: | Corrected value [-] | |||
Corrected setting for P-AXIS-00517 measurement input | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|