ID 110595

Value for drive encoder modulo range is outside permissible range.

Description

The parameter P-AXIS-00528 specifies the value range of the drive encoder,if the encoder supplies modulo positions. The CNC uses this value to handle encoder overflow. The given value is however invalid.

Response

Class

1

Warning message output and correct the parameter

Solution

Class

1

Correct parameter P-AXIS-00528.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Incorrect value [increments]

Incorrect value for modulo range P-AXIS-00528

%3:

Lower limit value [increments]

Minimum permissible value for P-AXIS-00528

%4:

Upper limit value [increments]

Maximum permissible value for P-AXIS-00528

%5:

Corrected value [increments]

Corrected value for encoder modulo range P-AXIS-00528

Error type

2, Error message on data transfer of parameter lists to controller.