ID 110602

Weighting factor for velocity of distance control for lowering movement exceeds maximum permissible value.

Description

The velocity (P-AXIS-00415) used for the lowering movement of the distance control (see FCT-M3) can be weighted with the parameter P-AXIS-00533 in per mille [0.1%]. However, the specified weighting factor is greater than permissible.

Response

Class

1

Warning, weighting factor for velocity P-AXIS-00533 is corrected.

Solution

Class

1

Correct parameter P-AXIS-00533.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected

%2:

Incorrect value [0.1%]

Invalid weighting value P-AXIS-00533

%3:

Upper limit value [0.1%]

Maximum permissible velocity weighting P-AXIS-00533

%4:

Corrected value [0.1%]

Corrected value for velocity weighting P-AXIS-00533

Error type

2, Error message on data transfer of parameter lists to controller.