ID 110602

Weighting factor for velocity of distance control for downward movement exceeds maximum permissible value.

Description

The velocity (P-AXIS-00415) used for the lowering movement of the distance control (see FCT-M3) can be weighted with the parameter P-AXIS-00533 ) in per mille [0.1 %]. However, the given weighting factor is greater than permissible.

Response

Class

1

Warning, weighting factor for velocity P-AXIS-00533 is corrected.

Solution

Class

1

Correct parameter P-AXIS-00533.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Error value [0,1%]

Invalid weighting value P-AXIS-00533

%3:

Upper limit value [0,1%]

Maximum permissible speed weighting P-AXIS-00533

%4:

Corrected value [0,1%]

Corrected value for speed weighting P-AXIS-00533

Error type

2, Error message by data transfer from parameter list into control device.