ID 110610

The process data for the 'probe_actuated' signal was not found in the cyclic process data.

Description

When configuring the SERCOS realtime status bits for the signal 'measuring probe ½' actuated', the process data element configured in P-AXIS-00679 (probe 1) or P-AXIS-00685 was not found in the configured cyclic process data.

Response

Class

1

Output of an error message containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset, in order to prevent the execution of measurement run or edge bending with incompletely configured probes.

Solution

Class

1

P-AXIS-00679/ or P-AXIS-00685 must be corrected.

Parameter

%1:

 

Log. Axis number

%2:

 

Incorrect value of P-AXIS-00679/or P-AXIS-00685

%3:

 

Drive type

Error type

2, Error message by data transfer from parameter list into control device.