ID 110617

Process data element for the 'probing_command_start' was not found in the cyclic process data.

Description

When configuring the SERCOS realtime control bits for the signal 'Command start probing', the process data element configured in P-AXIS-00699 was not found in the configured cyclic process data.

Response

Class

1

Output of an error message containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset, in order to prevent the execution of measurement run or edge bending with incompletely configured probes.

Solution

Class

1

P-AXIS-00699 must be corrected.

Parameter

%1:

 

Log. Axis number

%2:

 

Incorrect value of P-AXIS-00699

%3:

 

Drive type

Error type

2, Error message by data transfer from parameter list into control device.